Apple Power Macintosh G3 Minitower Dokumentacja Strona 257

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 256
Troubleshooting Symptom Charts/Error Chords - 23
Error Chords
One-part error chord
(sound of breaking
glass) sounds during
startup sequence
1 Disconnect IDE data cable from hard drive and reboot system.
If startup sequence is normal, initialize hard drive. Test unit
again with IDE data cable connected. If error chord still
sounds, replace hard drive.
2 Disconnect floppy drive cable from floppy drive and reboot
system. If startup sequence is normal, replace floppy drive.
3 Reseat processor module.
4 Replace logic board.
5 Replace processor module.
Przeglądanie stron 256