 Xserve (Late 2006/Early 2008)
073-1082 Rev. B
Logic Board
Replacement Instructions
Follow the instructions in this document carefully. Failure to follow these instructions could
damage your equipment and void its warranty.
Online instructions are available at http://www.apple.com/support/diy/.
Working Safely Inside the Xserve
Always touch the Xserve enclosure to discharge static electricity before you touch any
components inside the Xserve. To avoid generating static electricity, do not walk around the
room until you have nished working inside the server and have replaced the cover. To minimize
the possibility of damage due to static discharge, wear an antistatic wrist strap while you work
inside the Xserve.
Important: Hold PCI cards, FB-DIMMs, logic boards, processors, and other printed circuit boards
by their edges. Never touch the gold contacts or other exposed metallic components on the
boards. Handle the boards gently and don’t bend or ex them.
Warning: Always shut down the Xserve and disconnect the power cords before opening
it to avoid damaging its internal components or the components you are installing. Don’t
open the server while it is turned on. Even after you shut down the Xserve, its internal
components can be very hot. Let it cool before you open it.
Tools Required
The following tools are required for this procedure:
Phillips #1 screwdriver
Antistatic wrist strap (if available)
2 thermal grease syringes for replacing processor heat sinks (supplied with the part)
2 alcohol wipes for cleaning processors and heat sinks (supplied with the part)
Przeglądanie stron 0
1 2 3 4 5 6 ... 30 31

Podsumowanie treści

Strona 1 - Logic Board

 Xserve (Late 2006/Early 2008)073-1082 Rev. BLogic BoardReplacement InstructionsFollow the instructions in this document carefully. Failure to follow

Strona 2 - Thumbscrews

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 10Caution: Whenever you handle a heat sink, handle it from the slotted sides, not

Strona 3 - Opening the Xserve

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 11Caution: Each heat sink is connected to the logic board by a small 2-pin thermal

Strona 4 - Power Supplies

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 12ProcessorRelease the latch on the metal processor holder.1. Rotate the top of th

Strona 5 - FB-DIMMs

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 13Video Mezzanine Card (if installed)Remove the four 8-5-mm long Phillips screws t

Strona 6 - Airow Duct

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 14Logic BoardStudy the next four images for properly moving the logic board before

Strona 7 - Fan Array

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 15Caution: When transferring the logic board, be careful not to ex the logic boar

Strona 8

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 16Disconnect the optical drive cable from the logic board.2. Release the two locki

Strona 9 - Processor Heat Sinks

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 17Following the order shown, loosen the nine thumbscrews that secure the logic boa

Strona 10

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 18Xserve (Early 2008): Packing the Used Logic Board Important: This packing proced

Strona 11

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 19Place the logic board in the box, making sure it is component-side up and positi

Strona 12 - Processor

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 2Removing the Xserve from a RackAlert users that the server will be unavailable fo

Strona 13

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 20Installing the Replacement Logic BoardImportant: When replacing the logic board,

Strona 14

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 21Following the order shown, use a screwdriver to tighten, but not overtighten, th

Strona 15

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 22Replacing the ProcessorsUnsnap the protective plastic cover from the rst proces

Strona 16

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 23Use the edge of the package that the alcohol wipe came in as a spatula to spread

Strona 17

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 24Note: When installing the processor on the logic board, align the processor notc

Strona 18

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 25Rotate the top of the holder to the closed position.5. Engage the latch on the p

Strona 19

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 26Replacing the Backplane-to-Logic Board I/O CableFold the cable to a 90-degree an

Strona 20

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 27Replacing the Fan ArrayAlign the power connector on the fan array with its conne

Strona 21

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 28Tighten the ve Phillips screws that fasten the airow duct to the fan array, in

Strona 22 - Replacing the Processors

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 29Replacing the PCI Riser Cards and Expansion CardsAlign the riser with slot 2 on

Strona 23

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 3Opening the XserveLoosen the thumbscrews at the back of the top cover and slide t

Strona 24

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 30Changing the Ethernet ID LabelReplacing the logic board in the Xserve changes it

Strona 25

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 31Using the Updated Server Serial NumberWhen you use Server Assistant to install M

Strona 26

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 4Power SuppliesPull the handle to release the rst power supply and slide it out o

Strona 27 - Replacing the Airow Duct

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 5FB-DIMMsPush down the ejectors on the FB-DIMM slot.1. Holding the FB-DIMM by both

Strona 28 - Replacing the FB-DIMMs

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 6Airow DuctLoosen the ve captive Phillips screws that fasten the airow duct to

Strona 29 - Replacing the Power Supplies

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 7Fan ArrayLoosen the two captive thumbscrews that secure the fan array to the encl

Strona 30 - Closing the Xserve

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 8Backplane-to-Logic Board I/O CableDisconnect the backplane-to-logic board cable f

Strona 31

Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 9Processor Heat SinksNote: Server congurations with a single processor have a reg