 Xserve (Late 2006)
073-1100 Rev. A
Fan Array
Replacement Instructions
Follow the instructions in this document carefully. Failure to follow these instructions could
damage your equipment and void its warranty.
Online instructions are available at http://www.apple.com/support/diy/.
Working Safely Inside the Xserve
Always touch the Xserve enclosure to discharge static electricity before you touch any
components inside the Xserve. To avoid generating static electricity, do not walk around the
room until you have nished working inside the server and have replaced the cover. To minimize
the possibility of damage due to static discharge, wear an antistatic wrist strap while you work
inside the Xserve.
Warning: Always shut down the Xserve and disconnect the power cords before opening
it to avoid damaging its internal components or the components you are installing. Don’t
open the server while it is turned on. Even after you shut down the Xserve, its internal
components can be very hot. Let it cool before you open it.
Tools Required
The only tool required for this procedure is a Phillips #1 screwdriver.
Removing the Xserve from a Rack
Alert users that the server will be unavailable for a period of time.
Shut down the Xserve (see the Xserve User’s Guide for help) and then wait to let the Xserve
internal components cool.
Warning: Always shut down the Xserve before opening it to avoid damaging its internal
components or the components you want to install or remove. Dont open the Xserve
or try to install or remove items inside while it is turned on. Even after you shut down
the Xserve, its internal components can be very hot. Let it cool down for 5 to 10 minutes
before you open it.
1.
2.
Przeglądanie stron 0
1 2 3 4 5 6 7

Podsumowanie treści

Strona 1 - Fan Array

 Xserve (Late 2006)073-1100 Rev. AFan ArrayReplacement InstructionsFollow the instructions in this document carefully. Failure to follow these instru

Strona 2 - Opening the Xserve

Xserve (Late 2006) Fan Array Replacement Instructions 2Unplug all cables from the Xserve. Note: If you have trouble releasing a cable from the back p

Strona 3 - Airow Duct

Xserve (Late 2006) Fan Array Replacement Instructions 3Removing the Installed Fan ArrayNote: Before you can remove the fan array, you must remove the

Strona 4

Xserve (Late 2006) Fan Array Replacement Instructions 4Fan ArrayLoosen the two thumbscrews that secure the fan array to the enclosure. Note: The thum

Strona 5

Xserve (Late 2006) Fan Array Replacement Instructions 5Installing the Replacement Fan ArrayInstall the foam included in the replacement parts box on

Strona 6

Xserve (Late 2006) Fan Array Replacement Instructions 6Lower the airow duct into position on the logic board. Note: When installing the airow duct,

Strona 7 - Closing the Xserve

Xserve (Late 2006) Fan Array Replacement Instructions 7Closing the XserveReplace and secure the cover.Slide the Xserve back into the rack, and tighte